Modular magnetic soft robotic catheter enables visualized intervention in the pancreatobiliary tree

首次提交 2026-01-21 18:11
版本更新 2026-11-06 18:34
雷达观测 2026-11-09 11:19
arXiv ↗PDF ↗

摘要

Diagnosis and therapy in the pancreatobiliary tree are limited by access. Guidewires reach deep into the ducts but are blind, whereas cholangioscopes provide vision but are too large to readily enter the pancreatic body and tail, the cystic duct, or the gallbladder. At the millimeter scale of these ducts, every function added to a steerable catheter competes with steering for cross-section and adds bending stiffness. We present a 1.47-mm modular magnetic soft robotic catheter in which each function is built into the magnetic body, onto its surface, or onto the footprint of the camera, and we measured what each function costs in bending under bedside fields. Imaging and fiber Bragg grating (FBG) shape sensing accounted for most of this cost, whereas a compliant gripper, magnetic anchoring balloons, and a micrometer-thick ultrasound-triggered release shell together reduced the tip angle at 8 mT only from 70° to 64°. The anchoring balloon increased the gripping force about threefold without stiffening the catheter during navigation. In live pigs, the robotic catheter performed operator-initiated task-autonomous cannulation of the native papilla without sphincterotomy and was teleoperated under onboard vision 75 mm into the pancreatic duct and, without a guidewire, through the cystic duct into the gallbladder, whose lumen it imaged. Anchoring, grasping, and payload release were each demonstrated in vivo. Adding each function at a measured cost to steering allows a soft robot small enough for these ducts to intervene as well as navigate.

作者备注:31 pages, 7 figures, 1 table, 7 supplementary figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-06 18:34 · 最新观测版本

Modular magnetic soft robotic catheter enables visualized intervention in the pancreatobiliary tree

Diagnosis and therapy in the pancreatobiliary tree are limited by access. Guidewires reach deep into the ducts but are blind, whereas cholangioscopes provide vision but are too large to readily enter the pancreatic body and tail, the cystic duct, or the gallbladder. At the millimeter scale of these ducts, every function added to a steerable catheter competes with steering for cross-section and adds bending stiffness. We present a 1.47-mm modular magnetic soft robotic catheter in which each function is built into the magnetic body, onto its surface, or onto the footprint of the camera, and we measured what each function costs in bending under bedside fields. Imaging and fiber Bragg grating (FBG) shape sensing accounted for most of this cost, whereas a compliant gripper, magnetic anchoring balloons, and a micrometer-thick ultrasound-triggered release shell together reduced the tip angle at 8 mT only from 70° to 64°. The anchoring balloon increased the gripping force about threefold without stiffening the catheter during navigation. In live pigs, the robotic catheter performed operator-initiated task-autonomous cannulation of the native papilla without sphincterotomy and was teleoperated under onboard vision 75 mm into the pancreatic duct and, without a guidewire, through the cystic duct into the gallbladder, whose lumen it imaged. Anchoring, grasping, and payload release were each demonstrated in vivo. Adding each function at a measured cost to steering allows a soft robot small enough for these ducts to intervene as well as navigate.

查看此版本解读 →查看此版本原文 ↗