跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2603.14667 · v2

Comparative Analysis of 3D Convolutional and 2.5D Slice-Conditioned U-Net Architectures for MRI Super-Resolution via Elucidated Diffusion Models

首次提交 2026-03-16 07:48
版本更新 2026-11-13 14:26
雷达观测 2026-11-16 10:40
arXiv ↗PDF ↗

摘要

Magnetic resonance imaging (MRI) super-resolution (SR) methods that computationally enhance low-resolution acquisitions offer a software alternative to higher-field scanners. We study an elucidated diffusion model (EDM) framework for 2x in-plane brain MRI SR and compare two U-Net backbones: (i) a 3D convolutional U-Net that processes volumetric patches and (ii) a 2.5D slice-conditioned U-Net that super-resolves each slice while conditioning on its two neighbouring slices. All models are trained from scratch to convergence on 500 subjects of the NKI cohort of FOMO60K, with a separate 6-subject validation set for checkpoint selection, and evaluated on 70 held-out subjects with subject-level statistics against baselines (EDSR, Swin2SR, Res-SRDiff) trained on the same data. Neither architecture is better overall. On the degradation used in training the two are tied (37.72 dB PSNR for the 3D model and 37.70 dB for the 2.5D model), 0.2 dB ahead of EDSR. When the test degradation changes to k-space truncation, EDSR matches the diffusion models, and with added noise the 2.5D model is the most accurate method. When the test cohort changes to 70 subjects of an external dataset (IXI), the 3D model is the most accurate, 0.4 dB ahead of the best baseline and 0.9 dB ahead of the 2.5D model in foreground PSNR.

作者备注:v2: revised version resubmitted to IEEE Access; supersedes the results of v1. 10 pages, 8 figures, 6 tables

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-13 14:26 · 最新观测版本

Comparative Analysis of 3D Convolutional and 2.5D Slice-Conditioned U-Net Architectures for MRI Super-Resolution via Elucidated Diffusion Models

Magnetic resonance imaging (MRI) super-resolution (SR) methods that computationally enhance low-resolution acquisitions offer a software alternative to higher-field scanners. We study an elucidated diffusion model (EDM) framework for 2x in-plane brain MRI SR and compare two U-Net backbones: (i) a 3D convolutional U-Net that processes volumetric patches and (ii) a 2.5D slice-conditioned U-Net that super-resolves each slice while conditioning on its two neighbouring slices. All models are trained from scratch to convergence on 500 subjects of the NKI cohort of FOMO60K, with a separate 6-subject validation set for checkpoint selection, and evaluated on 70 held-out subjects with subject-level statistics against baselines (EDSR, Swin2SR, Res-SRDiff) trained on the same data. Neither architecture is better overall. On the degradation used in training the two are tied (37.72 dB PSNR for the 3D model and 37.70 dB for the 2.5D model), 0.2 dB ahead of EDSR. When the test degradation changes to k-space truncation, EDSR matches the diffusion models, and with added noise the 2.5D model is the most accurate method. When the test cohort changes to 70 subjects of an external dataset (IXI), the 3D model is the most accurate, 0.4 dB ahead of the best baseline and 0.9 dB ahead of the 2.5D model in foreground PSNR.

查看此版本解读 →查看此版本原文 ↗