跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2603.23647 · v4

λSplit: Self-Supervised Content-Aware Spectral Unmixing for Fluorescence Microscopy

首次提交 2026-03-25 02:42
版本更新 2026-11-19 05:52
雷达观测 2026-11-21 12:18
arXiv ↗PDF ↗

摘要

In fluorescence microscopy, spectral unmixing aims to recover individual fluorophore concentrations from spectral images that capture mixed fluorophore emissions. Since classical methods operate pixel-wise and rely on least-squares fitting, their performance degrades with increasingly overlapping emission spectra and higher levels of noise, suggesting that a data-driven approach that can learn and utilize a structural prior might lead to improved results. Learning-based approaches for spectral imaging do exist, but they are either not optimized for microscopy data or are developed for very specific cases that are not applicable to fluorescence microscopy settings. To address this, we propose λSplit, a physics-informed deep generative model that learns a conditional distribution over concentration maps using a hierarchical Variational Autoencoder. A fully differentiable Spectral Mixer enforces consistency with the image formation process, while the learned structural priors enable state-of-the-art unmixing and implicit noise removal. We demonstrate λSplit on 3 real-world datasets that we synthetically cast into a total of 66 challenging spectral unmixing benchmarks. We compare our results against a total of 10 baseline methods, including classical methods and a range of learning-based methods. Our results consistently show competitive performance and improved robustness in high noise regimes, when spectra overlap considerably, or when the spectral dimensionality is lowered, making λSplit a new state-of-the-art for spectral unmixing of fluorescent microscopy data. Importantly, λSplit is compatible with spectral data produced by standard confocal microscopes, enabling immediate adoption without specialized hardware modifications.

作者备注:14 pages, 25 pages supplement, 16 figures total, 14 tables total. Accepted at ECCV 2026

期刊信息:Computer Vision - ECCV 2026, Lecture Notes in Computer Science, vol. 17063, pp. 520-536, Springer, Cham (2026)

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v4,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v4 · 2026-11-19 05:52 · 最新观测版本

λSplit: Self-Supervised Content-Aware Spectral Unmixing for Fluorescence Microscopy

In fluorescence microscopy, spectral unmixing aims to recover individual fluorophore concentrations from spectral images that capture mixed fluorophore emissions. Since classical methods operate pixel-wise and rely on least-squares fitting, their performance degrades with increasingly overlapping emission spectra and higher levels of noise, suggesting that a data-driven approach that can learn and utilize a structural prior might lead to improved results. Learning-based approaches for spectral imaging do exist, but they are either not optimized for microscopy data or are developed for very specific cases that are not applicable to fluorescence microscopy settings. To address this, we propose λSplit, a physics-informed deep generative model that learns a conditional distribution over concentration maps using a hierarchical Variational Autoencoder. A fully differentiable Spectral Mixer enforces consistency with the image formation process, while the learned structural priors enable state-of-the-art unmixing and implicit noise removal. We demonstrate λSplit on 3 real-world datasets that we synthetically cast into a total of 66 challenging spectral unmixing benchmarks. We compare our results against a total of 10 baseline methods, including classical methods and a range of learning-based methods. Our results consistently show competitive performance and improved robustness in high noise regimes, when spectra overlap considerably, or when the spectral dimensionality is lowered, making λSplit a new state-of-the-art for spectral unmixing of fluorescent microscopy data. Importantly, λSplit is compatible with spectral data produced by standard confocal microscopes, enabling immediate adoption without specialized hardware modifications.

查看此版本解读 →查看此版本原文 ↗