← 研踪 PaperTrailarXiv:2605.12541 · v2
PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation
首次提交 2026-05-09 15:39
版本更新 2026-11-08 14:41
雷达观测 2026-11-10 12:16
摘要
Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway
作者备注:Accepted to NeurIPS 2026
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v2 · 2026-11-08 14:41 · 最新观测版本
PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation
Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway
查看此版本解读 →查看此版本原文 ↗