跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2605.12541 · v2

PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation

首次提交 2026-05-09 15:39
版本更新 2026-11-08 14:41
雷达观测 2026-11-10 12:16
arXiv ↗PDF ↗

摘要

Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway

作者备注:Accepted to NeurIPS 2026

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-08 14:41 · 最新观测版本

PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation

Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway

查看此版本解读 →查看此版本原文 ↗