跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2606.16364 · v3

Looking Is Not Picking: An Attention-Segment Account of Tool-Selection Failures in LLM Agents

首次提交 2026-06-15 15:58
版本更新 2026-11-22 17:33
雷达观测 2026-11-24 12:47
arXiv ↗PDF ↗

摘要

LLM agents mis-call tools, and the natural guess is that the model failed to see the right tool in a crowded harness. We show the opposite through a lens concurrent work sets aside -- the model's attention to labeled tool-definition segments. On real BFCL failures, by per-candidate attention argmax the model attends most to the correct tool 80% of the time (vs. 21% chance), and the gold is the under-attended segment on only 10%: it looks at the right tool and still picks wrong. This directly refutes the intuitive "crowded-harness / lost-in-the-middle" explanation: the failure is at the decision readout, not the harness, and we pin it there three ways. (1) Input vs. readout: repairing the prompt (reordering or duplicating the gold tool) recovers <=23% of failures, while readout-side interventions recover 59-91%. (2) Representation-invariance: two gold-pointed interventions in different representations -- an additive attention-logit bias and a residual-stream steering vector -- recover largely the same failures (per-task Jaccard 0.865 pooled, 0.79-0.91 per model), so the bottleneck is localized to the readout independent of which representation is poked. (3) A training-free, gold-free selector: per-segment attention closes most of the gold-free-vs-oracle gap on BFCL (+11.9 pts pooled function-name selection vs. +17.9-pt oracle headroom) and adds +14.9 pts on Seal-Tools; every model positive (exact McNemar p<=8e-4 each). Scopes differ: the causal attention-bias dose-response is bidirectional and monotonic on 10 mask-honoring models (3-32B), the full 0.5-32B span carrying only the correlational diagnostic; the deployable selector is evaluated on 5 single-turn models and does not yet transfer to a multi-turn loop.

作者备注:This submission is withdrawn by the author. Upon re-evaluation, I find the experimental design and validation in this version lack sufficient rigor, and the overall work does not meet the expected standard. I will conduct more careful experiments, strengthen the analysis, and submit a thoroughly revised manuscript when ready

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v3,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v3 · 2026-11-22 17:33 · 最新观测版本

Looking Is Not Picking: An Attention-Segment Account of Tool-Selection Failures in LLM Agents

LLM agents mis-call tools, and the natural guess is that the model failed to see the right tool in a crowded harness. We show the opposite through a lens concurrent work sets aside -- the model's attention to labeled tool-definition segments. On real BFCL failures, by per-candidate attention argmax the model attends most to the correct tool 80% of the time (vs. 21% chance), and the gold is the under-attended segment on only 10%: it looks at the right tool and still picks wrong. This directly refutes the intuitive "crowded-harness / lost-in-the-middle" explanation: the failure is at the decision readout, not the harness, and we pin it there three ways. (1) Input vs. readout: repairing the prompt (reordering or duplicating the gold tool) recovers <=23% of failures, while readout-side interventions recover 59-91%. (2) Representation-invariance: two gold-pointed interventions in different representations -- an additive attention-logit bias and a residual-stream steering vector -- recover largely the same failures (per-task Jaccard 0.865 pooled, 0.79-0.91 per model), so the bottleneck is localized to the readout independent of which representation is poked. (3) A training-free, gold-free selector: per-segment attention closes most of the gold-free-vs-oracle gap on BFCL (+11.9 pts pooled function-name selection vs. +17.9-pt oracle headroom) and adds +14.9 pts on Seal-Tools; every model positive (exact McNemar p<=8e-4 each). Scopes differ: the causal attention-bias dose-response is bidirectional and monotonic on 10 mask-honoring models (3-32B), the full 0.5-32B span carrying only the correlational diagnostic; the deployable selector is evaluated on 5 single-turn models and does not yet transfer to a multi-turn loop.

查看此版本解读 →查看此版本原文 ↗