← 研踪 PaperTrailarXiv:2611.02999 · v1
SyncHeC: Markerless Spatio-Temporal Hand-Eye Calibration via Differentiable Rendering and Continuous-Time Joint Optimization
首次提交 2026-11-02 20:03
版本更新 2026-11-02 20:03
雷达观测 2026-11-04 23:42
摘要
Markerless hand-eye calibration under continuous motion requires jointly resolving camera geometry and the time offset between images and joint states. We present SyncHeC (Synchronized Hand-Eye Calibration), a dense differentiable-rendering framework that estimates both from a single robot trajectory. Continuous-time forward kinematics makes latency differentiable, metric depth complements mask contours, and an offline planner combines spatial sensitivity with temporal excitation. Alternating updates support Eye-to-Hand, Eye-in-Hand, and multi-camera calibration. On a 7-DoF arm, one $6.5$\,s motion yields $0.21$\,cm translation error against a marker-board reference, $0.34$\,cm touch-test error, and $2.7$\,ms latency error relative to an $87$\,ms reference with $95\%$ uncertainty of $\pm1.5$\,ms. Against CM-Calib on matched recordings, translation and nominal latency errors improve by $3.7\times$ and $2.3\times$. Experiments span seven arms and four depth sensors. Compensating the recovered offset during policy training and deployment increases success by $8.1$ percentage points across six families and six tasks ($1{,}800$ matched pairs; paired $95\%$ confidence interval $[6.3,9.9]$ points).
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-02 20:03 · 最新观测版本
SyncHeC: Markerless Spatio-Temporal Hand-Eye Calibration via Differentiable Rendering and Continuous-Time Joint Optimization
Markerless hand-eye calibration under continuous motion requires jointly resolving camera geometry and the time offset between images and joint states. We present SyncHeC (Synchronized Hand-Eye Calibration), a dense differentiable-rendering framework that estimates both from a single robot trajectory. Continuous-time forward kinematics makes latency differentiable, metric depth complements mask contours, and an offline planner combines spatial sensitivity with temporal excitation. Alternating updates support Eye-to-Hand, Eye-in-Hand, and multi-camera calibration. On a 7-DoF arm, one $6.5$\,s motion yields $0.21$\,cm translation error against a marker-board reference, $0.34$\,cm touch-test error, and $2.7$\,ms latency error relative to an $87$\,ms reference with $95\%$ uncertainty of $\pm1.5$\,ms. Against CM-Calib on matched recordings, translation and nominal latency errors improve by $3.7\times$ and $2.3\times$. Experiments span seven arms and four depth sensors. Compensating the recovered offset during policy training and deployment increases success by $8.1$ percentage points across six families and six tasks ($1{,}800$ matched pairs; paired $95\%$ confidence interval $[6.3,9.9]$ points).
查看此版本解读 →查看此版本原文 ↗