跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.04053 · v1

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

首次提交 2026-11-03 06:47
版本更新 2026-11-03 06:47
雷达观测 2026-11-04 23:40
arXiv ↗PDF ↗

摘要

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-03 06:47 · 最新观测版本

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

查看此版本解读 →查看此版本原文 ↗