跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.05741 · v1

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

首次提交 2026-11-04 07:27
版本更新 2026-11-04 07:27
雷达观测 2026-11-05 10:08
arXiv ↗PDF ↗

摘要

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

作者备注:8 pages, 7 figures. Supplementary video in ancillary files. Sherry Choi and Sitao Sunny Li contributed equally to this work

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-04 07:27 · 最新观测版本

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

查看此版本解读 →查看此版本原文 ↗