跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.07950 · v1

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

首次提交 2026-11-05 20:47
版本更新 2026-11-05 20:47
雷达观测 2026-11-06 11:06
arXiv ↗PDF ↗

摘要

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.

作者备注:10 pages, 1 figure, 6 tables

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-05 20:47 · 最新观测版本

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.

查看此版本解读 →查看此版本原文 ↗