跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.11906 · v1

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

首次提交 2026-11-09 13:23
版本更新 2026-11-09 13:23
雷达观测 2026-11-10 13:18
arXiv ↗PDF ↗

摘要

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-09 13:23 · 最新观测版本

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

查看此版本解读 →查看此版本原文 ↗