Reliable medical laboratory automation requires robots to complete entire workflows in protocol order while handling changes during execution. A robot may execute each motion correctly yet fail the workflow by confusing visually similar stages or stalling after human intervention. We present Robo-MLT, a dual-system framework that couples explicit workflow monitoring with learned action generation. A vision--language planner composes an ordered atomic-skill sequence from the protocol and the initial workspace observation. A multiframe execution monitor detects when the active skill has completed or become infeasible, then advances the workflow or triggers replanning. A skill-conditioned vision--language--action policy generates the manipulation trajectories, and an asynchronous runtime coordinates it with the monitor. We evaluate Robo-MLT against four policy baselines and a VLM-based monitor baseline on blood gas analysis and blood sample tube sorting, with 50 nominal configurations per method and 20 sample-removal configurations. Robo-MLT achieves task success rates of 82\% and 70\%, exceeding $π_{0.5}$ by 30 and 22 percentage points, respectively. After an operator removes the sample being handled, the system revises the remaining plan and continues processing the other samples. These results indicate that, under the evaluated conditions, explicit workflow monitoring makes long-horizon laboratory manipulation more reliable and recoverable.

作者备注:12 pages,7 figures,5 tables,1 algorithm

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-09 19:27 · 最新观测版本

Robo-MLT: Dual-System Robotic Manipulation for Long-Horizon Medical Laboratory Tasks

Reliable medical laboratory automation requires robots to complete entire workflows in protocol order while handling changes during execution. A robot may execute each motion correctly yet fail the workflow by confusing visually similar stages or stalling after human intervention. We present Robo-MLT, a dual-system framework that couples explicit workflow monitoring with learned action generation. A vision--language planner composes an ordered atomic-skill sequence from the protocol and the initial workspace observation. A multiframe execution monitor detects when the active skill has completed or become infeasible, then advances the workflow or triggers replanning. A skill-conditioned vision--language--action policy generates the manipulation trajectories, and an asynchronous runtime coordinates it with the monitor. We evaluate Robo-MLT against four policy baselines and a VLM-based monitor baseline on blood gas analysis and blood sample tube sorting, with 50 nominal configurations per method and 20 sample-removal configurations. Robo-MLT achieves task success rates of 82\% and 70\%, exceeding $π_{0.5}$ by 30 and 22 percentage points, respectively. After an operator removes the sample being handled, the system revises the remaining plan and continues processing the other samples. These results indicate that, under the evaluated conditions, explicit workflow monitoring makes long-horizon laboratory manipulation more reliable and recoverable.

查看此版本解读 →查看此版本原文 ↗