跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.13513 · v1

Evidential Deep Learning with conditional entropy for glaucoma detection

首次提交 2026-11-10 11:39
版本更新 2026-11-10 11:39
雷达观测 2026-11-11 11:04
arXiv ↗PDF ↗

摘要

We propose a novel conditional entropy function as a basis for quantifying predictive uncertainty in Evidential Deep Learning (EDL) for glaucoma detection from retinal fundus images. Using the EyePACS-AIROGS-light-V2 and RIM-ONE-DL datasets for validation, we found that our proposed EDL model regularized by conditional entropy function produced uncertainty estimates with substantially lower calibration errors than Deep Ensembles, MC Dropout, post-hoc calibration and the conventional EDL framework based on Dempster uncertainty. To further probe our models' interpretability, we analyzed Grad-CAM heatmaps using a focus index representing spatial concentration. Compared with the other uncertainty quantification methods, EDL models exhibited greater separation between the index distributions of correctly and incorrectly classified fundus images. In particular, false negatives were associated with localized Grad-CAM activations that were displaced from the optic disc, consistent with its established clinical importance in glaucoma assessment. Overall, our findings suggest that our proposed EDL framework for glaucoma detection provides not only enhanced uncertainty calibration but also admits a more physiologically consistent interpretability.

作者备注:15 pages, 4 figures. To appear in TAAI 2026

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-10 11:39 · 最新观测版本

Evidential Deep Learning with conditional entropy for glaucoma detection

We propose a novel conditional entropy function as a basis for quantifying predictive uncertainty in Evidential Deep Learning (EDL) for glaucoma detection from retinal fundus images. Using the EyePACS-AIROGS-light-V2 and RIM-ONE-DL datasets for validation, we found that our proposed EDL model regularized by conditional entropy function produced uncertainty estimates with substantially lower calibration errors than Deep Ensembles, MC Dropout, post-hoc calibration and the conventional EDL framework based on Dempster uncertainty. To further probe our models' interpretability, we analyzed Grad-CAM heatmaps using a focus index representing spatial concentration. Compared with the other uncertainty quantification methods, EDL models exhibited greater separation between the index distributions of correctly and incorrectly classified fundus images. In particular, false negatives were associated with localized Grad-CAM activations that were displaced from the optic disc, consistent with its established clinical importance in glaucoma assessment. Overall, our findings suggest that our proposed EDL framework for glaucoma detection provides not only enhanced uncertainty calibration but also admits a more physiologically consistent interpretability.

查看此版本解读 →查看此版本原文 ↗