跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.27390 · v1

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

首次提交 2026-11-20 17:56
版本更新 2026-11-20 17:56
雷达观测 2026-11-23 14:16
arXiv ↗PDF ↗

摘要

On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute; CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier, capping calibration false-certification rate at 0.00%-3.50%.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-20 17:56 · 最新观测版本

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute; CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier, capping calibration false-certification rate at 0.00%-3.50%.

查看此版本解读 →查看此版本原文 ↗