← 研踪 PaperTrailarXiv:2611.31875 · v1
EEG-Jev: A Unified Single-Pass Decision Model for EEG
首次提交 2026-11-24 11:29
版本更新 2026-11-24 11:29
雷达观测 2026-11-25 10:15
摘要
EEG analysis spans choosing alternatives, judging statements, and rating ordered attributes, requiring calibratable probabilities with explicit meaning. We present EEG-Jev, a unified single-pass decision model for EEG. Given an EEG window, a question and an answer specification, one forward pass returns a typed readout: CHOICE gives a candidate distribution, NOUL a proposition probability, and SCORE an ordered-level distribution and expectation. One checkpoint is trained jointly and evaluated once on held-out splits of 35 public sources. Core raw outputs reach 54.08% balanced accuracy on Stieger2021 motor imagery, 70.45% on Sleep-EDF-SC sleep staging, 72.11% per window at threshold 0.5 on CHB-MIT seizure detection with 0.825 AUROC, and 1.700 MAE on 0-10 ds005292 pain ratings. Prior correction and temperature scaling lower negative log-likelihood from 0.766 to 0.606 on Sleep-EDF-SC and 0.166 to 0.019 on CHB-MIT, while direct readout cuts batch-1 latency from 122.43 to 63.11 ms (1.94-fold) against a matched-backbone generative comparator. Interactive demonstration and aggregate results: https://neuroimglab.github.io/EEG-Jev/.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-24 11:29 · 最新观测版本
EEG-Jev: A Unified Single-Pass Decision Model for EEG
EEG analysis spans choosing alternatives, judging statements, and rating ordered attributes, requiring calibratable probabilities with explicit meaning. We present EEG-Jev, a unified single-pass decision model for EEG. Given an EEG window, a question and an answer specification, one forward pass returns a typed readout: CHOICE gives a candidate distribution, NOUL a proposition probability, and SCORE an ordered-level distribution and expectation. One checkpoint is trained jointly and evaluated once on held-out splits of 35 public sources. Core raw outputs reach 54.08% balanced accuracy on Stieger2021 motor imagery, 70.45% on Sleep-EDF-SC sleep staging, 72.11% per window at threshold 0.5 on CHB-MIT seizure detection with 0.825 AUROC, and 1.700 MAE on 0-10 ds005292 pain ratings. Prior correction and temperature scaling lower negative log-likelihood from 0.766 to 0.606 on Sleep-EDF-SC and 0.166 to 0.019 on CHB-MIT, while direct readout cuts batch-1 latency from 122.43 to 63.11 ms (1.94-fold) against a matched-backbone generative comparator. Interactive demonstration and aggregate results: https://neuroimglab.github.io/EEG-Jev/.
查看此版本解读 →查看此版本原文 ↗