EEG-Jev: A Unified Single-Pass Decision Model for EEG

首次提交 2026-11-24 11:29
版本更新 2026-11-24 11:29
雷达观测 2026-11-25 10:15
arXiv ↗PDF ↗

摘要

EEG analysis spans choosing alternatives, judging statements, and rating ordered attributes, requiring calibratable probabilities with explicit meaning. We present EEG-Jev, a unified single-pass decision model for EEG. Given an EEG window, a question and an answer specification, one forward pass returns a typed readout: CHOICE gives a candidate distribution, NOUL a proposition probability, and SCORE an ordered-level distribution and expectation. One checkpoint is trained jointly and evaluated once on held-out splits of 35 public sources. Core raw outputs reach 54.08% balanced accuracy on Stieger2021 motor imagery, 70.45% on Sleep-EDF-SC sleep staging, 72.11% per window at threshold 0.5 on CHB-MIT seizure detection with 0.825 AUROC, and 1.700 MAE on 0-10 ds005292 pain ratings. Prior correction and temperature scaling lower negative log-likelihood from 0.766 to 0.606 on Sleep-EDF-SC and 0.166 to 0.019 on CHB-MIT, while direct readout cuts batch-1 latency from 122.43 to 63.11 ms (1.94-fold) against a matched-backbone generative comparator. Interactive demonstration and aggregate results: https://neuroimglab.github.io/EEG-Jev/.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-24 11:29 · 最新观测版本

EEG-Jev: A Unified Single-Pass Decision Model for EEG

EEG analysis spans choosing alternatives, judging statements, and rating ordered attributes, requiring calibratable probabilities with explicit meaning. We present EEG-Jev, a unified single-pass decision model for EEG. Given an EEG window, a question and an answer specification, one forward pass returns a typed readout: CHOICE gives a candidate distribution, NOUL a proposition probability, and SCORE an ordered-level distribution and expectation. One checkpoint is trained jointly and evaluated once on held-out splits of 35 public sources. Core raw outputs reach 54.08% balanced accuracy on Stieger2021 motor imagery, 70.45% on Sleep-EDF-SC sleep staging, 72.11% per window at threshold 0.5 on CHB-MIT seizure detection with 0.825 AUROC, and 1.700 MAE on 0-10 ds005292 pain ratings. Prior correction and temperature scaling lower negative log-likelihood from 0.766 to 0.606 on Sleep-EDF-SC and 0.166 to 0.019 on CHB-MIT, while direct readout cuts batch-1 latency from 122.43 to 63.11 ms (1.94-fold) against a matched-backbone generative comparator. Interactive demonstration and aggregate results: https://neuroimglab.github.io/EEG-Jev/.

查看此版本解读 →查看此版本原文 ↗