跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.34508 · v1

Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size Scaling

首次提交 2026-11-25 22:57
版本更新 2026-11-25 22:57
雷达观测 2026-11-26 12:28
arXiv ↗PDF ↗

摘要

Dual-domain networks combine projection and image processing for sparse-view low-dose computed tomography (CT). We quantify the contribution of angular interpolation before learning and distinguish its roles in sinogram initialisation and the image residual base. On synthetic parallel-beam data, parameter-free interpolation reduces noise-free missing-view mean absolute error by 99.7% relative to zero filling at 60 views. Full-view filtered back-projection (FBP) of the jointly learned completed sinogram adds 1.27 dB of peak signal-to-noise ratio (PSNR) over interpolated FBP. In a data-consistency dual-domain network (DC-DuNet), a 2x2 configuration ablation controls branch width, depth and training schedule while varying these placements and their associated input channels. After 20 epochs, the PSNR contrasts are +1.98 dB for sinogram initialisation and -2.16 dB for the interpolated image base; the image-base ranking also reverses during training. The sinogram-initialised variant exceeds an image-only U-Net by 0.96 dB at 60 views and 10% dose, and by 1.28 dB on independently generated synthetic data. The U-Net leads at higher view counts and with a shared interpolated image base. Without retraining, the variant retains a 0.12 dB advantage on held-out CHAOS abdominal CT under simulated degradation; the image-base contrast rounds to zero. The implemented projection/backprojection pair has empirical dominant gain of approximately 0.85NK, where N is image-grid width and K acquired view count. These results distinguish interpolation placement from network architecture and support NK normalisation for step calibration.

作者备注:12 pages, 3 figures, 3 tables

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-25 22:57 · 最新观测版本

Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size Scaling

Dual-domain networks combine projection and image processing for sparse-view low-dose computed tomography (CT). We quantify the contribution of angular interpolation before learning and distinguish its roles in sinogram initialisation and the image residual base. On synthetic parallel-beam data, parameter-free interpolation reduces noise-free missing-view mean absolute error by 99.7% relative to zero filling at 60 views. Full-view filtered back-projection (FBP) of the jointly learned completed sinogram adds 1.27 dB of peak signal-to-noise ratio (PSNR) over interpolated FBP. In a data-consistency dual-domain network (DC-DuNet), a 2x2 configuration ablation controls branch width, depth and training schedule while varying these placements and their associated input channels. After 20 epochs, the PSNR contrasts are +1.98 dB for sinogram initialisation and -2.16 dB for the interpolated image base; the image-base ranking also reverses during training. The sinogram-initialised variant exceeds an image-only U-Net by 0.96 dB at 60 views and 10% dose, and by 1.28 dB on independently generated synthetic data. The U-Net leads at higher view counts and with a shared interpolated image base. Without retraining, the variant retains a 0.12 dB advantage on held-out CHAOS abdominal CT under simulated degradation; the image-base contrast rounds to zero. The implemented projection/backprojection pair has empirical dominant gain of approximately 0.85NK, where N is image-grid width and K acquired view count. These results distinguish interpolation placement from network architecture and support NK normalisation for step calibration.

查看此版本解读 →查看此版本原文 ↗