跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.08863 · v1

What Limits mmWave Human-State Sensing for Robot Perception?

首次提交 2026-11-06 09:45
版本更新 2026-11-06 09:45
雷达观测 2026-11-09 10:16
arXiv ↗PDF ↗

摘要

Assistive robots and search-and-rescue platforms require reliable human state sensing in smoke, darkness, and privacy-sensitive environments, where cameras and LiDAR may be unreliable Millimeter-wave radar offers an alternative that works without ambient light, penetrates smoke, and does not capture visual appearance. However, the compact arrays that fit robot size, power, and cost budgets have limited apertures, producing joint-localization errors on the order of decimeters at a few meters, large enough to compromise the safety margins and tracking accuracy a robot depends on. Existing pipelines reduce pose error through frame fusion, multiple viewpoints, return selection, or stronger estimators, but examine one technique at a time, without relating its effect to a shared measurement limit or separating gains from added information from gains from estimator completion. We address this gap with a framework that models the human and environment as one time-varying scattering field and states a Cramer-Rao type error floor for joint localization as a function of bandwidth, aperture, signal-to-noise ratio, fused frame count, phase coherence, and visibility of retained returns. We then use existing frame fusion, multi viewpoint, return selection, and pose estimation methods as matched probes of this floor rather than as competing pipelines. Under the evaluated conditions, experiments on three datasets and a live deployment show these strategies move joint localization error in the predicted directions, for example lowering mean per-joint position error from about 97 to 65 mm with a second viewpoint, while a stronger estimator mainly lowers overall error by completing joints the measurement cannot resolve. These results give the robotics community a principled basis for deciding whether to prioritize observation design or estimator capacity when deploying reliable mmWave human sensing.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-06 09:45 · 最新观测版本

What Limits mmWave Human-State Sensing for Robot Perception?

Assistive robots and search-and-rescue platforms require reliable human state sensing in smoke, darkness, and privacy-sensitive environments, where cameras and LiDAR may be unreliable Millimeter-wave radar offers an alternative that works without ambient light, penetrates smoke, and does not capture visual appearance. However, the compact arrays that fit robot size, power, and cost budgets have limited apertures, producing joint-localization errors on the order of decimeters at a few meters, large enough to compromise the safety margins and tracking accuracy a robot depends on. Existing pipelines reduce pose error through frame fusion, multiple viewpoints, return selection, or stronger estimators, but examine one technique at a time, without relating its effect to a shared measurement limit or separating gains from added information from gains from estimator completion. We address this gap with a framework that models the human and environment as one time-varying scattering field and states a Cramer-Rao type error floor for joint localization as a function of bandwidth, aperture, signal-to-noise ratio, fused frame count, phase coherence, and visibility of retained returns. We then use existing frame fusion, multi viewpoint, return selection, and pose estimation methods as matched probes of this floor rather than as competing pipelines. Under the evaluated conditions, experiments on three datasets and a live deployment show these strategies move joint localization error in the predicted directions, for example lowering mean per-joint position error from about 97 to 65 mm with a second viewpoint, while a stronger estimator mainly lowers overall error by completing joints the measurement cannot resolve. These results give the robotics community a principled basis for deciding whether to prioritize observation design or estimator capacity when deploying reliable mmWave human sensing.

查看此版本解读 →查看此版本原文 ↗